Troubleshooting method for self-service queuing and calling system in banks:
1. Check if the serial port selection is correct in the window settings, usually defaulting to com1;
2. Check if the connection is correct and in the following order: extend a line from the calling host's com port to the RS232A port of the communication controller, and then connect the RS485A port of the communication controller to the repeater through a network cable. The repeater is connected to the wired caller;
3. Check if the hardware calling protocol is selected as "QJZ-02" in other settings 1 of the system settings;
4. Check if there is a hardware malfunction. The communication controller has 5 input and output channels, and you can try replacing the circuit. Other hardware can be solved by replacing it;
5. Check if the communication on the COM port of the calling host is normal and if the baud rate is 9600bps.
The self-service queuing and calling system of banks is something we need to have contact with when handling business and other situations. Therefore, when such situations occur, we need to conduct troubleshooting to minimize the efficiency of user transactions.
2024-01-10
What are the classifications of self-service terminals?2024-01-12
Customized process for self-service terminals2024-01-12
Installation and operation guide for dynamic facial recognition access control system2024-01-12
WeChat appointment facial recognition visitor registration system2024-01-12
What functions do the self-service terminals of the vehicle management office need to haveShenzhen Qianhai Yinbotong Technology Co., Ltd
Shenzhen Xiaojinxiang Technology Co., Ltd
Address: Building 1, Qianhai Shenzhen Hong Kong Cooperation Zone, Nanshan District, Shenzhen
Address: Building 5, Houhai Xufa Industrial Park, Lou Village, Guangming New District, Shenzhen
Phone: 0755-82233088/18902835484/13631657778
Contact person: Mr. Gong 13631657778, Miss Gong 18902835484
Email:mandy@rostonetech.com
Website:Www.rostonech.com